Foshan Tanfon Energy Technology Co., Ltd.
Products
Contact Us
  • Contact Person : Ms. luo lily
  • Company Name : Foshan Tanfon Energy Technology Co., Ltd.
  • Tel : 86-757-82702658
  • Fax : 86-757-82706975
  • Address : Guangdong,foshan,46 Heping Road Shiwan Chancheng Foshan
  • Country/Region : China
  • Zip : 528000

Grid tie off grid Inverter/Three Phase Inverter/380VAC Output Inverter

Grid tie off grid Inverter/Three Phase Inverter/380VAC Output Inverter
Product Detailed
Grid Inverter/Three Phase Inverter/380VAC Output Inverter 1.Load pump/lift and industrial appliances. 2.Pure sine wave output.

Grid tie off grid Inverter/Three Phase Inverter/380VAC Output Inverter

 

Grid Inverter/Three Phase Inverter/380VAC Output Inverter feature

Capacity: 1KW--100KW (1) super wide input voltage: 285V-475V(2) completely controlled by CPU, LCD automatic page turning display(3) protection against output short-circuit; Against overload, and when you throw off its load, it will turn on the unit automatically. (4)working for single phase and three phase.

110V/220V single phase ;240v/380v/415V/440V option.(5) with charger built-in, its charging current is 10A----156A. (6) different DC voltage:  24V, 48V, 96V, 384V for optional (7) make it with 3 pcs PCB box,it is more stable design.

(8)this kinds inverter can take pump or lift, and other industrial use

  

Grid Inverter/Three Phase Inverter/380VAC Output Inverter specification

Model

T1K

T3K

T5K

T10K

T15K

T20K

T30K

T60K

T100K

Power

1KW

3KW

5KW

10KW

15KW

20KW

30KW

60KW

100KW

Power Factor

0.8

  Phase

3 phase 4 wire and ground

Wave form

Pure sine wave

 Frequency Range

45 – 65Hz

Input

  Voltage Range

380V± 20%(3 phase), phase voltage 220V

  Rectifier

3 phase 6 pulses, 12 pulses is optional

Output

  Crest Factor

3: 01

  Rated voltage

380/400/415V optional

  Phase voltage

200 - 244VAC,

 Transient response

+/-5%, 10ms

  Total-harmonic    distortion

< 3% linear load, < 5%( nonlinear load)

  Short circuit current

Short current for 0.1s (200% current)

  Overload capacity

Overload 125% for 10 ms, 125%-150% for 1min. automatically resume when load become normal

Bypass

  Type

Static state + manual maintenance bypass

  Input Phase

3 phase 4 wire and ground

  Input voltage range

15% - 25% (the front control panel selectable)

  Transfer time

Inverter / bypass transfer switch time(Overload): 0ms inverter / bypass transfer switch time (fault inverter) 1ms

  Remote signaling

Dry contact (battery low, battery discharging, bypass/ fault); output 12Vdc/80mA, Optional parts

  Communication interface

RS232

  Operate condition

0-40 degree Celsius,Less than 95% ,without condensing

  Noise at 1 M

less than 60 dB

  Degree of protection

IP20

  Applicable Standards

EN50091-1-EMC EN50091-2liv. A

  Product size(mm)

560*230*570

590*470*730

900*600*1380

1200*900*1820

  product weight(Kg)

30

40

54

104

125

190

380

690

800